This consultation closes at 11:59 p.m. on:
December 11, 2025
Proposal summary
This proposal is for an amendment to existing Environmental Compliance Approval No. 1431-BTWRCL issued on October 22, 2020 for 102 Main Street. The purpose of this amendment is to request a change from the previously approved Norweco Modulair CR-90 treatment plant treating wastewater from the facility at 106 Main Street with five Ecoflo units.
Location details
Site address
102 Main Street
Bloomfield,
ON
Canada
Site location details
County of Prince Edward
Site location map
The location pin reflects the approximate area where environmental activity is taking place.
View this location on a map opens link in a new windowProponent(s)
Ian Laurie Estates Inc.
102 Main Street
Bloomfield,
ON
K0K 1G0
Canada
Proposal details
This proposal is for an amendment to an existing Environmental Compliance Approval No. 1431-BTWRCL, issued on October 22, 2020, for 102 Main Street, Bloomfield.
The purpose of the amendment application is to request a change from the previously approved Norweco Modulair CR-90 treatment plant treating wastewater from the commercial facility at 106 Main Street with five Ecoflo Biofilter treatment units. It is also requested a decrease in the theoretical daily design sewage flow attributed to the commercial facility from 18,450 liters per day to 13,000 liters per day based on historical flow data. It is proposed a new Class 4 Sewage System to service a newly constructed three bedroom cottage located at 102 Main Street and an extension of the five year construction time frame.
The owners of the lands at 102 Main Street (Ian Laurie & Kirsten Musgrove) have agreed to a transfer easement to construct, maintain, operate, repair, and upgrade a septic system for the treatment of sewage from 106 Main Street, Bloomfield, Ontario. The site currently operates under the authority of an Environmental Compliance Approval number 1431-BTWRCL issued on October 22, 2020 to Ian Jonathan Laurie with a rated capacity of 19,525 liters per day. Based on historical flow data we are requesting a decrease from 19,525 liters per day to 16,475 liters per day.
Wastewater Treatment System 1 - The three bedroom house located at 102 Main Street will continue to be serviced by an existing class 4 treatment system (septic tank and leaching bed).
Wastewater Treatment System 2 – Servicing the Commercial Facility at 106 Main Street. The current ECA lists a proposed Norweco Modulair CR-50 treatment plant. It is proposed to replace the Norweco CR-50 treatment unit with five Ecoflo® Biofilter treatment units.
Wastewater Treatment System 3 – New Class 4 sewage system consisting of a septic tank, pump chamber and raised filter bed to service a three bedroom cottage located at 102 Main Street.
Supporting materials
View materials in person
Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.
Get in touch with the office listed below to find out if materials are available.
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Connect with us
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Comment
Let us know what you think of our proposal.
Have questions? Get in touch with the contact person below. Please include the ERO number for this notice in your email or letter to the contact.Read our commenting and privacy policies.
Submit online
Submit by mail
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada