BCP IV SERVICE STATION LP O/A BG FUELS - Approval for variance from the Liquid Fuels Handling Code

Instrument type: Approval for variance from the Liquid Fuels Handling Code

ERO number
019-8637
Ministry reference number
WO 14272249
Notice type
Instrument
Act
Technical Standards & Safety Act, 2000
Posted by
Technical Standards and Safety Authority (TSSA)
Notice stage
Proposal
Proposal posted
Comment period
May 2, 2024 - June 1, 2024 (30 days) Open
Last updated

This consultation closes at 11:59 p.m. on:
June 1, 2024

Proposal summary

BCP IV SERVICE STATION LP O/A BG FUELS wants to replace several tank and dispenser sump entry boots (fittings that connect piping to a containment system) with retrofit boots made by Icon Products.

Location details

Site address

657 JOHN ST N
AYLMER, ON
N5H 2B6
Canada

Site location details

Gas station

Proponent(s)

BCP IV SERVICE STATION LP O/A BG FUELS
140 ALLSTATE PARKWAY, UNIT 503
MARKHAM, ON
L3R 5Y8
Canada

Proposal details

Liquid Fuels Handling Code (LFHC) Requirements that Would Not be Met:

1.3.1. Equipment installed at a facility or on a highway tank shall be approved and installed in accordance with the requirements of this Code and the manufacturer’s instructions, and shall be appropriate for the service for which it is intended.

 

Why the Code Would Not be Met

Clause 1.3.1 of the Liquid Fuels Handling code requires that equipment be approved to a Canadian standard; however, there is no corresponding Underwriters’ Laboratories of Canada standard.

These retrofit boots will allow the applicant to make repairs to the dispenser sumps without having to excavate and replace the entire sump.

 

Safety Assessment

The retrofit boots have been evaluated by a third-party lab and meet the Underwriters’ Laboratory standard "UL 2447 Outline of Investigation for Containment Sumps, Fittings and Accessories for Fuels".  The retrofit boots have also shown good cold weather performance.

TSSA assesses that there is likely to be no environmental impact should this variance be granted.

Supporting materials

View materials in person

Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.

Get in touch with the office listed below to find out if materials are available.

Technical Standards and Safety Authority
Address

345 Carlingview Drive
Toronto, ON
M9W 6N9
Canada

Office phone number

Comment

Let us know what you think of our proposal.

Have questions? Get in touch with the contact person below. Please include the ERO number for this notice in your email or letter to the contact.

Read our commenting and privacy policies.

Submit online

Submit by mail

Contact

Marek Kulik

Phone number
Email address
Office
Technical Standards and Safety Authority
Address

345 Carlingview Drive
Toronto, ON
M9W 6N9
Canada

Office phone number

Connect with us

Contact

Marek Kulik

Phone number
Email address
Office
Technical Standards and Safety Authority
Address

345 Carlingview Drive
Toronto, ON
M9W 6N9
Canada

Office phone number

Sign up for notifications

We will send you email notifications with any updates related to this consultation. You can change your notification preferences anytime by visiting settings in your profile page.

Follow this notice