Résumé de la proposition
This proposal is for amendment to an existing Environmental Compliance Approval (industrial sewage works) No. 0836-BYTSTU for existing stormwater management facilities to service a proposed building, with rooftop control, and small pockets of paved areas of the existing Procter and Gamble Inc. site located at 355 University Avenue in Belleville.
Détails de l'emplacement
Adresse du site
355 University Avenue
City of Belleville,
ON
Canada
Carte de l'emplacement du site
L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.
Afficher cet emplacement sur une carte opens link in a new windowPromoteur(s)
Procter & Gamble Inc.
4711 Yonge Street North
Toronto,
ON
M2N 5M4
Canada
Détails de la proposition
This proposal is for amendment to an existing Environmental Compliance Approval (industrial sewage works) No. 0836-BYTSTU for existing stormwater management facilities to service a proposed building, with rooftop control, and small pockets of paved areas of the existing Procter and Gamble Inc. site located at 355 University Avenue in Belleville.
The project consists of proposed development works including new parking lots (north of the site), proposed building (0.52 hectares) north of the existing building with rooftop control, and small pockets of paved areas. In the existing condition, the site is serviced by an existing dry pond, ditches, and oil grit separator (OGS). There is an existing amended Environmental Compliance Approval (ECA) permit in place for the existing dry pond, ditches, and OGS. The existing amended ECA permit number is 0836-BYTSTU (issued May 17, 2021).
The proposed stormwater management (SWM) strategy is to introduce proposed SWM features in the form of proposed dry pond (with active storage volume of 2156 cubic meters), controlled by 225 millimetres orifice and 1.25 meter weir, and 16 metre emergency spillway. The proposed dry pond provides quantity control for the proposed north parking lot. The runoff from the proposed dry pond is conveyed by grassed swale with bottom width of 1 meter, side slopes of 3H:1V and longitudinal slope of 0.3%, which provides some degree of treatment. Additional treatment is provided by the existing ditches and downstream OGS.
Future developments involving additional parking lot areas will require similar at-source or upstream proposed SWM controls. The proposed building (0.52 hectares) with rooftop control has a controlled release rate of 42 litres/second/hectares or 0.022 cubic metres per second.
Documents justificatifs
Consulter les documents en personne
Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.
Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Communiquer avec nous
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Commentaire
Dites-nous ce que vous pensez de notre proposition.
Vous avez des questions? Contactez la personne-ressource indiquée ci-dessous. Veuillez indiquer le numéro du REO de l’avis dans votre courriel ou votre lettre à la personne-ressource.Lire nos politiques relatives aux commentaires et à la protection de la vie privée.
Soumettre en ligne
Soumettre par la poste
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada