Proposal summary

This proposal is for a new Environmental Compliance Approval (sewage) to install an onsite sewage system to service Clovermead Adventure Farm facilities, located at 11302 Imperial Road, in the Township of Malahide, County of Elgin, Ontario.

Location details

Site address

11302 Imperial Road
Malahide, ON
Canada

Site location map

The location pin reflects the approximate area where environmental activity is taking place.

View this location on a map opens link in a new window

Proponent(s)

Clovermead Apiaries Limited
11302 Imperial Road
Malahide, ON
N5H 2R3
Canada

Proposal details

This proposal is for a new Environmental Compliance Approval (sewage) for Clovermead Apiaries Limited to install an onsite sewage system to service the Clovermead Adventure Farm facilities, located at 11302 Imperial Road in the Township of Malahide, County of Elgin, Ontario.

The proposed sewage disposal system is sized to operate with a total daily flow of 40,000 litres per day. The proposed sewage works include a collection system, treatment area consisting of septic tanks, and discharge of effluent to a raised absorption trench bed, which consists of:

  1. five (5) pump tanks, equipped with simplex sewage pumps, to convey wastewater from Site buildings to the treatment area;
  2. one (1) existing septic tank and one (1) proposed septic tank equipped with an effluent filter, and two (2) pump tanks, equipped with simplex effluent pumps, to convey wastewater from the staff quarters and north storage shed/washroom to the treatment area;
  3. four (4) septic tanks, connected in series, with an effluent filter at the outlet of the fourth septic tank (treatment area);
  4. one (1) pump tank, equipped with duplex effluent pumps, to time-dose the raised absorption trench leaching bed; and
  5. a raised fill-based absorption trench leaching bed, consisting of distribution piping, to be constructed in two (2) zones, with each zone consisting of four (4) cells.

Supporting materials

View materials in person

Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.

Get in touch with the office listed below to find out if materials are available.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Comment

Commenting is now closed.

The comment period was from August 9, 2024
to September 23, 2024

Connect with us

Contact

Sign up for notifications

We will send you email notifications with any updates related to this consultation. You can change your notification preferences anytime by visiting settings in your profile page.

Follow this notice