Clovermead Apiaries Limited - Environmental Compliance Approval (sewage)

La traduction française de cet avis n'est pas disponible. Nous nous excusons pour le dérangement.

Type d'acte: Environmental Compliance Approval (sewage)

Numéro du REO
019-9043
Numéro de référence du ministère
1352-D7AJX8
Type d'avis
Instrument
Loi
Environmental Protection Act, R.S.O. 1990
Affiché par
Ministry of the Environment, Conservation and Parks
Étape de l'avis
Proposition
Proposition affichée
Période de consultation
Du 9 août 2024 au 23 septembre 2024 (45 jours) Fermé
Dernière mise à jour

Cette consultation a eu lieu :

du 9 août 2024
au 23 septembre 2024

Résumé de la proposition

This proposal is for a new Environmental Compliance Approval (sewage) to install an onsite sewage system to service Clovermead Adventure Farm facilities, located at 11302 Imperial Road, in the Township of Malahide, County of Elgin, Ontario.

Détails de l'emplacement

Adresse du site

11302 Imperial Road
Malahide, ON
Canada

Carte de l'emplacement du site

L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.

Afficher cet emplacement sur une carte opens link in a new window

Promoteur(s)

Clovermead Apiaries Limited
11302 Imperial Road
Malahide, ON
N5H 2R3
Canada

Détails de la proposition

This proposal is for a new Environmental Compliance Approval (sewage) for Clovermead Apiaries Limited to install an onsite sewage system to service the Clovermead Adventure Farm facilities, located at 11302 Imperial Road in the Township of Malahide, County of Elgin, Ontario.

The proposed sewage disposal system is sized to operate with a total daily flow of 40,000 litres per day. The proposed sewage works include a collection system, treatment area consisting of septic tanks, and discharge of effluent to a raised absorption trench bed, which consists of:

  1. five (5) pump tanks, equipped with simplex sewage pumps, to convey wastewater from Site buildings to the treatment area;
  2. one (1) existing septic tank and one (1) proposed septic tank equipped with an effluent filter, and two (2) pump tanks, equipped with simplex effluent pumps, to convey wastewater from the staff quarters and north storage shed/washroom to the treatment area;
  3. four (4) septic tanks, connected in series, with an effluent filter at the outlet of the fourth septic tank (treatment area);
  4. one (1) pump tank, equipped with duplex effluent pumps, to time-dose the raised absorption trench leaching bed; and
  5. a raised fill-based absorption trench leaching bed, consisting of distribution piping, to be constructed in two (2) zones, with each zone consisting of four (4) cells.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Commentaire

La consultation est maintenant terminée.

La période de consultation a eu lieu du 9 août 2024
au 23 septembre 2024

Communiquer avec nous

Contact

S'inscrire pour obtenir des avis

Nous vous enverrons des avis par courriel accompagnés de toute mise à jour liée à cette consultation. Vous pouvez modifier vos préférences relatives à l'avis en tout temps en allant à votre page de profil où se trouvent vos paramètres.