Truly Green Farms Ltd. - Environmental Compliance Approval (sewage)

Instrument type: Environmental Compliance Approval (sewage)

ERO number
019-9312
Ministry reference number
4289-D9NPY9
Notice type
Instrument
Act
Environmental Protection Act, R.S.O. 1990
Posted by
Ministry of the Environment, Conservation and Parks
Notice stage
Proposal
Proposal posted
Comment period
October 29, 2024 - December 13, 2024 (45 days) Open
Last updated

This consultation closes at 11:59 p.m. on:
December 13, 2024

Proposal summary

This proposal is for a new Environmental Compliance Approval (M&P sewage) for stormwater management works serving the Truly Green Farms Greenhouse development site, located at 162 Bloomfield Road located in Chatham, Ontario.

Location details

Site address

162 Bloomfield Road
Chatham, ON
Canada

Site location map

The location pin reflects the approximate area where environmental activity is taking place.

View this location on a map opens link in a new window

Proponent(s)

Truly Green Farms Ltd.
162 Bloomfield Road
Chatham, ON
N7M 0R4
Canada

Proposal details

This proposal is for a new Environmental Compliance Approval (M&P sewage) for stormwater management works serving the Truly Green Farms Greenhouse development site, located at 162 Bloomfield Road located in Chatham, Ontario.

This application is for a new wet pond stormwater management facility, discharging to surface waters via Lake St. Clair. The stormwater management works consist of the following:

  • roof water drainage pipe systems, swales, and on-site storm sewers, discharging roof top runoff and other surface runoff to stormwater detention pond;
  • one stormwater management detention/wet pond having an active storage volume of 13,260.9 cubic metres with a maximum active water depth of 2.26 metres for the 1:100-year storm event, discharging a maximum total release rate of 418 litres per second into the Payne and Backus Drain;
  • one irrigation/stormwater management reservoir is designed to be built in the future. It will collect roof water and be used for irrigation purposes of the crops;
  • one emergency overflow spillway directed to the Payne and Backus Drain;
  • one outlet structure containing a 375 millimetres diametres outlet pipe, flap gate and containment valve.

Supporting materials

View materials in person

Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.

Get in touch with the office listed below to find out if materials are available.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Comment

Let us know what you think of our proposal.

Have questions? Get in touch with the contact person below. Please include the ERO number for this notice in your email or letter to the contact.

Read our commenting and privacy policies.

Submit online

Submit by mail

Contact

Connect with us

Contact

Sign up for notifications

We will send you email notifications with any updates related to this consultation. You can change your notification preferences anytime by visiting settings in your profile page.

Follow this notice