This consultation closes at 11:59 p.m. on:
November 27, 2026
Proposal summary
This proposal is for an amendment to Environmental Compliance Approval No. 4505-5L2Q44, including the consolidation of sewage works approved under TA-32-91 for the establishment, modification, and consolidation of sewage works servicing Martyrs’ Shrine in Midland, Ontario.
Location details
Site address
16163 Highway West
Tay,
ON
Canada
Site location details
Lot 16 and 17, Concession 3
Site location map
The location pin reflects the approximate area where environmental activity is taking place.
View this location on a map opens link in a new windowProponent(s)
The Jesuit Fathers of Upper Canada Holding Corporation
16163 Highway 12 West
Tay,
ON
L4R 4K5
Canada
Proposal details
This proposal is for an amendment to Environmental Compliance Approval No. 4505-5L2Q44, including the consolidation of sewage works approved under TA-32-91 for the establishment, modification, and consolidation of sewage works servicing Martyrs’ Shrine in Midland, Ontario.
The proposed sewage works will collect, convey, treat, and dispose of domestic sewage generated by existing and proposed facilities throughout the property.
The sewage works will include sanitary collection infrastructure, septic tanks, pumping stations, forcemains, flow equalization facilities, a packaged wastewater treatment plant with phosphorus treatment, and subsurface disposal facilities. Existing sewage works throughout the property will be consolidated under a single Environmental Compliance Approval.
The proposed treatment system has a design capacity of approximately 65,000 litres per day, with flow equalization provided to accommodate variations in sewage generation associated with pilgrimage activities and peak visitation. Estimated sewage flows are approximately 41,275 litres per day during non-pilgrimage periods and up to approximately 121,275 litres per day during peak pilgrimage periods.
Treated effluent will be discharged to an expanded subsurface disposal system for final dispersal into the ground. The proposed upgrades are intended to improve effluent quality and provide adequate treatment and disposal capacity for facilities throughout the property.
Supporting materials
View materials in person
Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.
Get in touch with the office listed below to find out if materials are available.
40 St. Clair Avenue West
Floor 2
Toronto,
ON
M4V 1M2
Canada
Connect with us
Contact
Client Services and Permissions Branch
40 St. Clair Avenue West
Floor 2
Toronto,
ON
M4V 1M2
Canada
Comment
Let us know what you think of our proposal.
Have questions? Get in touch with the contact person below. Please include the ERO number for this notice in your email or letter to the contact.Read our commenting and privacy policies.
Submit online
Submit by mail
Contact
Client Services and Permissions Branch
40 St. Clair Avenue West
Floor 2
Toronto, ON
M4V 1M2
Canada