Albuna Express Ltd. - Environmental Compliance Approval (sewage)

La traduction française de cet avis n'est pas disponible. Nous nous excusons pour le dérangement.

Type d'acte: Environmental Compliance Approval (sewage)

Numéro du REO
019-8604
Numéro de référence du ministère
9910-CY8HJ4
Type d'avis
Instrument
Loi
Environmental Protection Act, R.S.O. 1990
Affiché par
Ministry of the Environment, Conservation and Parks
Étape de l'avis
Décision
Décision publiée
Période de consultation
Du 17 juin 2024 au 1 août 2024 (45 jours) Fermé
Dernière mise à jour

Cette consultation a eu lieu :

du 17 juin 2024
au 1 août 2024

Résumé de la décision

An amendment to the Environmental Compliance Approval is granted to Albuna Express Ltd. for the stormwater management works serving the agricultural greenhouse site, located at 306 County Road 18 in Leamington, Ontario.

Détails de l'emplacement

Adresse du site

306 County Road 18
Municipality of Leamington, ON
Canada

Carte de l'emplacement du site

L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.

Afficher cet emplacement sur une carte opens link in a new window

Promoteur(s)

Albuna Express Ltd.
306 County Road 18
Municipality of Leamington, ON
N8H 3V5
Canada

Détails de la décision

An amendment to the Environmental Compliance Approval is granted to Albuna Express Ltd. for the stormwater management works serving the agricultural greenhouse site, located at 306 County Road 18 in Leamington, Ontario.

The approved stormwater management works serving Phase 4 greenhouse and surrounding area of approximately 9.24 hectares, is comprised of:

  • stormwater quality control
  • stormwater quantity control
  • erosion control works

It includes:

  1. one oil & grit separator unit (3612WQB as manufactured by ADS Hancor or approved equal), serving a parking area of 0.12 hectares, with a sediment storage volume of 1000 litres and oil storage volume of 500 litres;
  2. roof water drainage pipe systems, swales and on-site storm sewers, discharging roof top runoff and other surface runoff to the Phase 4 stormwater detention pond;
  3. one stormwater management detention/wet pond having a total storage volume of 6,086.4 cubic metres with a maximum active water depth of 1.350 metres for the 100 year storm event, complete with an outlet structure comprising a catchbasin manhole with a 200 millimetres containment valve and a 200 millimetres diameter outlet pipe, discharging a maximum release rate of 74 litres per second into the Sturgeon Creek Drain to the south of the proposed property;
  4. One emergency overflow swale

Commentaires reçus

Par l'entremise du registre

0

Par courriel

0

Par la poste

0
Consulter les commentaires soumis par l'entremise du registre

Effets de la consultation

No comments were received.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

How to Appeal

Cet avis de décision peut être porté en appel. Vous avez jusqu’à 15 jours à partir du 12 novembre 2024 pour entamer le processus d’appel.

Veuillez lire les renseignements suivants attentivement pour en savoir plus sur le processus d’appel.

Comment interjeter appelClick to Expand Accordion

Start the process to appeal

If you’re an Ontario resident, you can start the process to appeal this instrument decision.

First, you’ll need to seek leave (i.e. get permission) from the relevant appellate body to appeal the decision.

If the appellate body grants leave, the appeal itself will follow.

Seek leave to appeal

To seek leave to appeal, you need to do these three things:

  1. prepare your application
  2. provide notice to the minister
  3. mail your application to three parties

1. Prepare your application

You’ll need to prepare an application. You may wish to include the following things in your application:

  1. A document that includes:
    • your name, phone number, fax number (if any), and/or email address
    • the ERO number and ministry reference number (located on this page)
    • a statement about whether you are a resident in Ontario
    • your interest in the decision, and any facts you want taken into account in deciding whether you have an interest in the decision
    • the parts of the instrument that you’re challenging
    • whether the decision could result in significant harm to the environment
    • the reason(s) why you believe that no reasonable person – having regard to the relevant law and to any government policies developed to guide decisions of that kind – could have made the decision
    • the grounds (facts) you’ll be using to appeal
    • the outcome you’d like to see
  2. A copy of the instrument (approval, permit, order) that you you are seeking leave to appeal. You’ll find this in the decision notice on the Environmental Registry
  3. Copies of all supporting documents, facts and evidence that you’ll be using to appeal
What is considered

The appeal body will consider the following two questions in deciding whether to grant you leave to appeal:

  1. is there is good reason to believe that no reasonable person, with respect to the relevant law and to any government policies developed to guide decisions of that kind, could have made the decision?
  2. could the decision you wish to appeal result in significant harm to the environment?

2. Provide your notice

You’ll need to provide notice to the Minister of the Environment, Conservation and Parks that you’re seeking leave to appeal.

In your notice, please include a brief description of the:

  • decision that you wish to appeal
  • grounds for granting leave to appeal

You can provide notice by email at minister.mecp@ontario.ca or by mail at:

College Park 5th Floor, 777 Bay St.
Toronto, ON
M7A 2J3

3. Mail your application

You’ll need to mail your application that you prepared in step #1 to each of these three parties:

  • appellate body
  • issuing authority (the ministry official who issued the instrument)
  • proponent (the company or individual to whom the instrument was issued)

Autorité compétente
Sherif Hegazy M Sc. P. Eng
Manager

Environmental Permission Branch
135 St Clair Avenue West
7th Floor
Toronto, ON
M4V 1P5
Canada

416 562 7910

Proponent(s)

Albuna Express Ltd.
306 County Road 18
Municipality of Leamington, ON
N8H 3V5
Canada


Organe d’appel

Registrar, Ontario Land Tribunal
655 Bay Street, Suite 1500
Toronto, Ontario
M5G 1E5
(416) 212-6349
(866) 448-2248
OLT.Registrar@ontario.ca

About the Ontario Land Tribunal


Inclure les éléments suivants:

Numéro du REO
019-8604
Numéro de référence du ministère
9910-CY8HJ4

Il ne s'agit pas d'un avis juridique. Veuillez vous reporter à la Charte des droits environnementaux de 1993 pour connaître les exigences exactes prévues par la loi. Consultez un avocat si vous avez besoin d'aide avec le processus d'appel.

Communiquer avec nous

Contact

S'inscrire pour obtenir des avis

Nous vous enverrons des avis par courriel accompagnés de toute mise à jour liée à cette consultation. Vous pouvez modifier vos préférences relatives à l'avis en tout temps en allant à votre page de profil où se trouvent vos paramètres.

Suivre cet avis

Proposition initiale

Numéro du REO
019-8604
Numéro de référence du ministère
9910-CY8HJ4
Type d'avis
Instrument
Loi
Environmental Protection Act, R.S.O. 1990
Affiché par
Ministry of the Environment, Conservation and Parks
Proposition affichée

Période de consultation

17 juin 2024 - 1 août 2024 (45 days)

Détails de la proposition

The proposal is for an amendment to Environmental Compliance Approval No. 1155-CHV3QD for Albuna Express Ltd. stormwater management works serving Albuna Express Ltd. phase 4 Greenhouse Expansion, located at 306 County Road 18, in the Municipality of Leamington, Ontario.

The stormwater management works comprise of Stormwater Quality Control, Quantity Control, and Erosion Control works, and includes on-site storm sewers, roof water drainage pipe systems, swales, one stormwater detention/wet pond, one oil grit separator and one emergency overflow swale. The proposed works will discharge to an outlet structure with an outlet pipe and a containment valve inside the structure.

These will discharge into the Sturgeon Creek Drain located north of King’s Highway No. 3.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Commentaire