Résumé de la décision

We granted a new Environmental Compliance Approval for a sewage treatment works servicing 1048547 Ontario Inc. operating as Skotidakis Goat Farm.

Détails de l'emplacement

Adresse du site

185 County Road 10
United Counties of Prescott and Russell
East Hawkesbury, ON
Canada

Carte de l'emplacement du site

L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.

Afficher cet emplacement sur une carte opens link in a new window

Promoteur(s)

1048547 Ontario Inc. operating as Skotidakis Goat Farm
185 County Road
East Hawkesbury, ON
K0B 1P0
Canada

Détails de la décision

Decision on instrument

We granted a new Environmental Compliance Approval for a sewage treatment works servicing 1048547 Ontario Inc. operating as Skotidakis Goat Farm. It is located at 185 County Road 10 in the Township of East Hawkesbury, Ontario. Skotidakis operates a diary farm that manufactures cheese based products.

The approved treatment works include:

  • an existing lift station
  • an anaerobic selector silo
  • an aerobic biological treatment basin
  • a solids/liquid separation unit
  • a sludge storage lagoon
  • tertiary filtration system

The industrial plant is designed to treat an average and peak day flows of 400 and 600 m3/day respectively discharging to the Rigaud River. The Ministry will require weekly and monitoring effluent leaving the plant and has imposed effluent criteria. The modificaitons include withdrawal of water from the Rigaud River to cool the plant's process equipment and the return of the cooling combined with treated effluent as a means to of diluting it before its return to the river. The ECA has placed a restriction on the temperature increase of the returning water and maximum waste loading. Skotidakis has submitted an a Permit to Take Water Application in addition to the ECA.

The attached document is intended for posting on the Environmental Registry in order to provide the reader with the substantive content of the issued instrument. Please note the official version may be differently formatted or otherwise contain minor variations from this version.

Commentaires reçus

Par l'entremise du registre

1

Par courriel

0

Par la poste

1
Consulter les commentaires soumis par l'entremise du registre

Effets de la consultation

Summary of comment(s)

Skotidakis comment 210859 provided in French on 2017/08/25 and translated in English The comment pertained to the construction of a new WWTP and use of the Rigaud River as a receiver. It cited concerns with respect to low river flows in the summer, an increase of biochemical oxygen demand, an increase in phosphorus and acute toxicity as result of higher ammonia.

Ministry's response

The Ministry has addressed all of these concerns in its Environmental Compliance Approval. The ECA does not allow the release of effleunt to the river when flows are at or below 0.5 m3/s. During periods when the effluent is below this value effluent will be stored in the onsite lagoon. The ECA stipulates final effluent compliance limits as 10 mg/L for CBOD5, 0.1 mg/L for total phosphorus and TAN limits of 1 mg/l for summer and 3 mg/L winter respectively. Acute toxicity testing is required to ensure non-toxic effluent with respect to ammonia. Finally the ECA stipulates that chlorides in the final effluent must be at or below 1,000 mg/L.The Ministry believes that the addition of a new WWTP will not adversely impact the quality of the Rigaud's River.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Environmental Approvals Access and Service Integration Branch
Address

135 St. Clair Avenue West
1st floor
Toronto, ON
M4V 1P5
Canada

Office phone number

How to Appeal

Cet avis de décision peut être porté en appel. Vous avez jusqu’à 15 jours à partir du 19 juin 2019 pour entamer le processus d’appel.

Veuillez lire les renseignements suivants attentivement pour en savoir plus sur le processus d’appel.

Comment interjeter appelClick to Expand Accordion

For instrument decisions published on or after June 1, 2021, please refer to the updated instructions for information on how to appeal a decision.

Appeal process for decisions published before June 1, 2021

If you’re an Ontario resident, you can start the process to appeal this instrument decision.

First, you’ll need to seek leave (i.e. get permission) from the relevant appellate body to appeal the decision.

If the appellate body grants leave, the appeal itself will follow.

Seek leave to appeal

To seek leave to appeal, you need to do these three things:

  1. prepare your application
  2. provide notice to the minister
  3. mail your application to three parties

1. Prepare your application

You’ll need to prepare an application. You may wish to include the following things in your application:

  1. A document that includes:
    • your name, phone number, fax number (if any), and/or email address
    • the ERO number and ministry reference number (located on this page)
    • a statement about whether you are a resident in Ontario
    • your interest in the decision, and any facts you want taken into account in deciding whether you have an interest in the decision
    • the parts of the instrument that you’re challenging
    • whether the decision could result in significant harm to the environment
    • the reason(s) why you believe that no reasonable person – having regard to the relevant law and to any government policies developed to guide decisions of that kind – could have made the decision
    • the grounds (facts) you’ll be using to appeal
    • the outcome you’d like to see
  2. A copy of the instrument (approval, permit, order) that you you are seeking leave to appeal. You’ll find this in the decision notice on the Environmental Registry
  3. Copies of all supporting documents, facts and evidence that you’ll be using to appeal
What is considered

The appeal body will consider the following two questions in deciding whether to grant you leave to appeal:

  1. is there is good reason to believe that no reasonable person, with respect to the relevant law and to any government policies developed to guide decisions of that kind, could have made the decision?
  2. could the decision you wish to appeal result in significant harm to the environment?

2. Provide your notice

You’ll need to provide notice to the Minister of the Environment, Conservation and Parks that you’re seeking leave to appeal.

In your notice, please include a brief description of the:

  • decision that you wish to appeal
  • grounds for granting leave to appeal

You can provide notice by email at minister.mecp@ontario.ca or by mail at:

College Park 5th Floor, 777 Bay St.
Toronto, ON 
M7A 2J3

3. Mail your application

You’ll need to mail your application that you prepared in step #1 to each of these three parties:

  • appellate body
  • issuing authority (the ministry official who issued the instrument)
  • proponent (the company or individual to whom the instrument was issued)

Autorité compétente
Youssouf Kalogo
Senior Wastewater Engineer

Environmental Assessment and Permissions Branch
135 St Clair Avenue West
Floor 1
Toronto, ON
M4V 1P5
Canada

416-314-7995

Proponent(s)

1048547 Ontario Inc. operating as Skotidakis Goat Farm
185 County Road
East Hawkesbury, ON
K0B 1P0
Canada


Organe d’appel

Environmental Review Tribunal
Attention: The Secretary
655 Bay Street
Floor 15
Toronto, Ontario
M5G 1E5
(416) 212-6349
(866) 448-2248
OLT.Registrar@ontario.ca

About the Environmental Review Tribunal


Inclure les éléments suivants:

Numéro du REO
013-1069
Numéro de référence du ministère
0179-AMEKEL

Il ne s'agit pas d'un avis juridique. Veuillez vous reporter à la Charte des droits environnementaux de 1993 pour connaître les exigences exactes prévues par la loi. Consultez un avocat si vous avez besoin d'aide avec le processus d'appel.

Communiquer avec nous

Contact

S'inscrire pour obtenir des avis

Nous vous enverrons des avis par courriel accompagnés de toute mise à jour liée à cette consultation. Vous pouvez modifier vos préférences relatives à l'avis en tout temps en allant à votre page de profil où se trouvent vos paramètres.

Suivre cet avis

Proposition initiale

Numéro du REO
013-1069
Numéro de référence du ministère
0179-AMEKEL
Type d'avis
Instrument
Loi
Environmental Protection Act, R.S.O. 1990
Affiché par
Ministry of the Environment, Conservation and Parks
Proposition affichée

Période de consultation

18 septembre 2018 - 2 novembre 2018 (45 days)

Détails de la proposition

Description of instrument

This proposal is for a new Environmental Compliance Approval for an industrial sewage treatment works servicing 1048547 Ontario Inc. operating as Skotidakis Goat Farm located at 185 County Road 10 in the Township of East Hawkesbury, Ontario.

The industrial sewage treatment works is comprised of a wastewater treatment plant, which consists of:

  • an existing lift station,
  • an anaerobic selector silo,
  • an aerobic biological treatment basin,
  • a solids/liquid separation unit,
  • a sludge storage lagoon, and
  • tertiary filtration system.

The plant will withdraw water from the Rigaud River to cool its process equipment and return the water combined with the treated effluent to the river.

Skotidakis is submitting a Permit to Take Water Application to the Ministry. The industrial sewage treatment plant is designed to have a maximum flow of 600,000 litres/day and will discharge to the Rigaud River.

The Ministry will require monitoring of the industrial wastewater and stormwater effluent leaving the plant.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Environmental Approvals Access and Service Integration Branch
Address

135 St. Clair Avenue West
1st floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Commentaire

La consultation est maintenant terminée.

Cette consultation a eu lieu 18 septembre 2018
au 2 novembre 2018

Communiquer avec nous

Contact