Miller Paving Limited - Environmental Compliance Approval (sewage)

La traduction française de cet avis n'est pas disponible. Nous nous excusons pour le dérangement.

Type d'acte: Environmental Compliance Approval (sewage)

Numéro du REO
019-9044
Numéro de référence du ministère
9283-D63UZ7
Type d'avis
Instrument
Loi
Environmental Protection Act, R.S.O. 1990
Affiché par
Ministry of the Environment, Conservation and Parks
Étape de l'avis
Proposition Mis à jour
Proposition affichée
Période de consultation
Du 9 août 2024 au 23 septembre 2024 (45 jours) Fermé
Dernière mise à jour

Update Announcement

This proposal notice has been updated on April 07, 2026 to advise the public that this application is still under active review. The original proposal date and comment period have not been altered.

Cette consultation a eu lieu :

du 9 août 2024
au 23 septembre 2024

Résumé de la proposition

This proposal is for a new Environmental Compliance Approval (sewage) for Miller Paving Limited to establish stormwater management works to service a proposed industrial manufacturing plant, located at 175 Bethridge Road, in the City of Toronto, Ontario.

Détails de l'emplacement

Adresse du site

175 Bethridge Road
Toronto, ON
Canada

Carte de l'emplacement du site

L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.

Afficher cet emplacement sur une carte opens link in a new window

Promoteur(s)

Miller Paving Limited
281 Hillmount Road
Suite 101
Markham, ON
L6C 2S3
Canada

Détails de la proposition

This proposal is for a new Environmental Compliance Approval (sewage) for Miller Paving Limited to establish stormwater management works to service a proposed industrial manufacturing plant for collection, transmission, treatment and disposal of stormwater run-off from the lands located at 175 Bethridge Road, in the City of Toronto, Ontario.

The proposed stormwater management works include an underground storage tank, complete with storm sewers. Runoff generated on the site will be captured through a series of double catch basins and conveyed through 200-525 millimetre diameter storm sewers into a stormwater facility before ultimately discharging to the existing 600 millimetre culvert at the southeast corner of the site.

Storage is provided within the stormwater facility, proposed pipes and the structures for storm events up to the 100-year. Stormwater from the Site will be attenuated though an orifice tube into the Jellyfish Filter, and then discharged to the existing 600 millimetre culvert. Furthermore, stormwater runoff generated from the plant’s operation area, where there is potential contamination, will be conveyed overland to the water recycle facility.

The flows up to the major (100-year) storm event generated in the operation area will be contained/stored in the compartment of the water recycle facility and will be pumped back to the plant to be re-used for the plant operations. The grading and servicing have been designed in this manner to avoid discharging any contaminated stormwater off site.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Commentaire

La consultation est maintenant terminée.

La période de consultation a eu lieu du 9 août 2024
au 23 septembre 2024

Communiquer avec nous

Contact

S'inscrire pour obtenir des avis

Nous vous enverrons des avis par courriel accompagnés de toute mise à jour liée à cette consultation. Vous pouvez modifier vos préférences relatives à l'avis en tout temps en allant à votre page de profil où se trouvent vos paramètres.

Suivre cet avis