Cette consultation se termine à 23 h 59 le :
21 février 2026
Résumé de la proposition
This proposal is for a new Environmental Compliance Approval (sewage) for the upgrading of existing wastewater disposal for Camp Barcovan Trailer Park located at 133 Carter Road, Quinte West, Ontario.
This upgrading is necessary due to the underperformance of the existing undersized distribution beds.
Détails de l'emplacement
Adresse du site
133 Carter Road
Carrying Place
City of Quinte West,
ON
Canada
Détails de l'emplacement du site
Camp Barcovan Tent and RV Park
Carte de l'emplacement du site
L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.
Afficher cet emplacement sur une carte opens link in a new windowPromoteur(s)
825678 Ontario Inc.
133 Carter Road
Carrying Place,
ON
K0K 1L0
Canada
Détails de la proposition
This proposal is for a new Environmental Compliance Approval (sewage) for the upgrading of existing wastewater disposal for Camp Barcovan Trailer Park located at 133 Carter Road, Quinte West, Ontario.
This upgrading is necessary due to the underperformance of the existing undersized distribution beds from insufficient wastewater retention in secondary treatment, leading to system failures. A new distribution bed is to be constructed directly to the north of the occupied park, to receive all wastewater from the park.
The Camp, located on Stoneburg Cove connected to Lake Ontario, is occupied by 129 serviced trailers, 18 unserviced tent/ trailer sites, 2 cabins, a hall, residence, and dump station, all serviced by five Class 4 septic systems and supplied by water from Stoneburg Cove.
The wastewater disposal for the Camp, designed for 59,350 litres per day, will consist of five wastewater collection systems, each collecting wastewater through existing in-ground collection, to be discharged by gravity to its own central retention tank system; flowing by gravity discharge to a suitably sized pump chamber for each system; containing duplexed pumps, discharging by forcemain to a central balancing and dosing tank system; and to a new subsurface distribution bed. All pump chambers in each of the five systems and the central balancing/dosing tank will be protected by high level audio and visual alarms with battery back-up.
Documents justificatifs
Consulter les documents en personne
Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.
Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Communiquer avec nous
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Commentaire
Dites-nous ce que vous pensez de notre proposition.
Vous avez des questions? Contactez la personne-ressource indiquée ci-dessous. Veuillez indiquer le numéro du REO de l’avis dans votre courriel ou votre lettre à la personne-ressource.Lire nos politiques relatives aux commentaires et à la protection de la vie privée.
Soumettre en ligne
Soumettre par la poste
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada