John Brian Warden operating as Warden Waste Site - Environmental Compliance Approval (waste)

La traduction française de cet avis n'est pas disponible. Nous nous excusons pour le dérangement.

Type d'acte: Environmental Compliance Approval (waste)

Numéro du REO
026-1097
Numéro de référence du ministère
1615-DY8PDA
Type d'avis
Instrument
Affiché par
Ministry of the Environment, Conservation and Parks
Étape de l'avis
Proposition
Proposition affichée
Période de consultation
Du 22 octobre 2026 au 6 décembre 2026 (45 jours) Ouvert
Dernière mise à jour

Cette consultation se termine à 23 h 59 le :
6 décembre 2026

Résumé de la proposition

This proposal is for the renewal of Environmental Compliance Approval No. 9193-C7Y5J6 for John Brian Warden operating as Warden Waste Site for a hauled sewage disposal site.

Détails de l'emplacement

Adresse du site

19648 Airport Road
Lot 3 and 4, Concession 1
Township of South Glengarry, ON
Canada

Carte de l'emplacement du site

L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.

Afficher cet emplacement sur une carte opens link in a new window

Promoteur(s)

John Brian Warden operating as Warden Waste Site
19255 County Road 2
Summerstown
Township of South Glengarry, ON
K0C 2E0
Canada

Détails de la proposition

Hauled sewage, commonly known as septage, is the waste material removed from portable toilets, sewage holding tanks and septic systems. Untreated hauled sewage from holding tanks and septic tanks may be disposed of on land in accordance with an Environmental Compliance Approval (ECA) issued under the Environmental Protection Act (EPA).

This proposal is for the renewal of Environmental Compliance Approval No. 9193-C7Y5J6 for John Brian Warden operating as Warden Waste Site for a hauled sewage disposal site.

Other information:

Site Details

  • Application type: renewal
  • Total useable area: 20 hectares
  • Type of disposal: surface spreading and storage lagoon
  • Number of lagoons: 1

Highlights of Proposed Approval Requirements

  • Prior to operating at the Site, the Company shall develop written procedures covering the following:
    • procedures for reporting to the Ministry, and municipal authorities as required in the event a spill occurs at the Site
    • a list of the personnel responsible for operations at the Site
  • The Company shall ensure that all personnel involved in the operation of this hauled sewage disposal site are aware of the requirements of this Approval and are trained in Spill Prevention
  • Spills of a pollutant that cause or may cause an adverse effect are to be reported to the Ministry's Spills Action Centre and the Company shall take appropriate remedial action to limit the impact
  • The Company must ensure that no unnecessary off-Site effects, such as vermin, vectors, odour, dust, litter, noise or traffic, result from the operation of this Site
  • Written records must be maintained in a log book that documents daily operations as well as any spills that occur and any complaints received
  • No hauled sewage shall be spread or disposed of at the Site when the ground is frozen, ice-covered or snow covered
  • No hauled sewage shall be spread at the Site under conditions where hauled sewage may runoff or discharge from the Site
  • Hauled sewage cannot be spread during winter months
  • The approval sets out a maximum spreading rate. In addition, spreading cannot take place within specified distances of sensitive features such as surface water, wells and residences, or on steeper sloped land
  • Prior to the spreading of hauled sewage, the operator shall ensure the useable spreading area is clearly flagged or digitally designated to clearly identify setbacks from sensitive features and any areas where spreading is not allowed
  • No processed organic waste, grease trap waste or other waste, other than hauled sewage, shall be disposed of at the Site
  • 3,500 cubic metres of hauled sewage (including, residential, commercial, institutional, and industrial) proposed to be stored at this site
  • Hauled sewage will be stored in a lagoon cell with a total capacity of 3,500 cubic metres
  • The storage must be designed and constructed according to specified standards set out in the approval
  • The storage must be operated in accordance with specified standards set out in the approval including minimum freeboard requirements

Other

Prior to the spreading of hauled sewage, the operator is responsible for ensuring that all necessary approvals, licences or permits that may be required from other authorities, such as the local municipality, conservation authority, MNR and OMAFA, have been acquired.

Documents justificatifs

Consulter les documents en personne

Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.

Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.

Client Services and Permissions Branch
Address

40 St. Clair Avenue West
Floor 2
Toronto, ON
M4V 1M2
Canada

Office phone number

Commentaire

Dites-nous ce que vous pensez de notre proposition.

Vous avez des questions? Contactez la personne-ressource indiquée ci-dessous. Veuillez indiquer le numéro du REO de l’avis dans votre courriel ou votre lettre à la personne-ressource.

Lire nos politiques relatives aux commentaires et à la protection de la vie privée.